 IP137A SERIES IP137A SERIES IP337A SERIES IP337A SERIES
LM137A SERIES LM137A SERIES
1
1 2
2
3 3
1.5 AMP NEGATIVE ADJUSTABLE VOLTAGE REGULATOR
FEATURES
* OUTPUT VOLTAGE RANGE OF: 1.25 TO 40V FOR STANDARD VERSION 1.25 TO 50V FOR -HV VERSION * 1% OUTPUT VOLTAGE TOLERANCE
Pin 1 - ADJ. Pin 2 - VOUT Case - VIN
Pin 1 - ADJ. Pin 2 - VOUT Case - VIN
K Package - TO-3
R Package - TO-66
1
2
3
123
* 0.3% LOAD REGULATION * 0.01% / V LINE REGULATION
Pin 1 - ADJ. Pin 2 - VIN Pin 3 - VOUT Case - VIN Pin 1 - ADJ. Pin 2 - VIN Pin 3 - VOUT Case - VIN
T Package - TO-220
!
G Package - TO-257
* COMPLETE SERIES OF PROTECTIONS: * CURRENT LIMITING * THERMAL SHUTDOWN * SOA CONTROL
123
Pin 1 - ADJ. Pin 2 - VIN Pin 3 - VOUT
Pin 1 - ADJ. Pin 2 - VIN Pin 3 - VOUT
SG Package - SMD1 CERAMIC SURFACE MOUNT
IG Package - TO-257 (Isolated)
ABSOLUTE MAXIMUM RATINGS (Tcase = 25C unless otherwise stated)
VI-O IO PD Tj Tstg Input - Output Differential Voltage Output Current Power Dissipation Operating Junction Temperature Range Storage Temperature
Telephone +44(0)1455 556565. Fax +44(0)1455 552612. E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
- Standard - HV Series
40V 50V Internally limited Internally limited See Order Information Table -65 to 150C
Prelim. 7/00
Semelab plc.
IP137A SERIES IP137A SERIES IP337A SERIES IP337A SERIES
IP137A , IP137AHV LM137A , LM137AHV Min. Typ. Max. -1.238 -1.220 -1.25 -1.25 0.005 0.010 5 0.1 10 0.2 0.002 60 70 66 80 65 IOUT = 10mA to IMAX 0.2 1.0 2.0 2.5 1.2 1.5 0.24 0.2 2.2 0.4 0.4 0.6 0.3 0.003 2.3 5 3 3 7 5 100 2 5 6 5 3 3.2 1 0.8 1.5 1 VOUT 5V VOUT 5V IOUT = 10mA to IMAX TJ = -55 to 150C Thermal Regulation Ripple Rejection IADJ Adjust Pin Current Adjust Pin Current Change IMIN Minimum Load Current tp = 10ms VOUT = -10V f = 120Hz TJ = -55 to 150C TJ = -55 to 150C VIN - VOUT = 3V to 40V VIN - VOUT = 3V to 50V VOUT 5V VOUT 5V TA = 25C CADJ = 0 CADJ = 10mF TJ = -55 to 150C -1.262 -1.280 0.010 0.030 25 0.5 50 1 0.020
LM137A SERIES LM137A SERIES
Parameter
Test Conditions IOUT = 10mA IOUT = 10mA to IMAX VIN - VOUT = 3V to VMAX P PMAX TJ = -55 to 150C VIN - VOUT = 3V to VMAX TJ = -55 to 150C IOUT = 10mA to IMAX
IP137 , IP137HV LM137 , LM137HV Min. Typ. Max. -1.225 -1.200 -1.25 -1.250 0.010 0.020 15 0.3 20 0.3 0.002 60 66 77 65 0.5 2 3 2.5 1.2 1.5 0.24 0.2 2.2 0.4 0.4 0.6 0.3 0.003 2.3 5 3 3 7 5 1 0.8 100 5 5 6 5 3 3.2 -1.275 -1.300 0.020 0.050 25 0.5 50 1 0.02
Units V V
VREF
Reference Voltage
DVOUT Line Regulation 1 DIOUT DVOUT Load Regulation 1 DIOUT
%/V mV % mV % %/W dB dB
mA mA
DIADJ
(HV SERIES)
TJ = -55 to 150C VIN - VOUT 40V VIN - VOUT 10V VIN - VOUT 15V ICL Current Limit TJ = -55 to 150C VIN - VOUT = 40V VIN - VOUT = 50V
mA
A
(HV SERIES)
DVOUT Temperature TJ = -55 to 150C DTEMP Stability TA = +125C DVOUT Long Term Stability DTIME t = 1000 Hrs
en RMS Output Noise (% of VOUT) RqJC Thermal Resistance Junction to Case f = 10 Hz to 10 kHz TA = 25C K Package R Package G Package
% % %
C/W
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to heating effects are covered under thermal regulation specifications. Load regulation is measured at a point 1/8" from the bottom of the package for the TO-3 and TO-66 packages, at the junction of the wide and narrow portion of the output lead for the SMD1 package, and 1/8" below the base of the package on the output pin of the TO-257 package. 2) Test Conditions unless otherwise stated: VIN - VOUT = 5V , IOUT = 0.5A , PMAX = 20W , IMAX = 1.5A VMAX = 40V for standard series , 50V for HV series.
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612. E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
Prelim. 7/00
IP137A SERIES IP137A SERIES IP337A SERIES IP337A SERIES
IP337AHV Min. Typ. Max. -1.238 -1.220 -1.25 -1.25 0.005 0.010 5 0.1 10 0.2 0.002 60 70 66 80 65 IOUT = 10mA to IMAX 0.2 1.0 2.0 2.5 1.2 1.5 0.24 0.2 2.2 0.4 0.4 0.6 0.3 0.003 2.3 4 3 5 100 2 5 6 5 3 3.5 1 0.8 1.5 1 VOUT 5V VOUT 5V IOUT = 10mA to IMAX TJ = 0 to 125C Thermal Regulation Ripple Rejection IADJ Adjust Pin Current Adjust Pin Current Change IMIN Minimum Load Current tp = 10ms VOUT = 10V f = 120Hz TJ = 0 to 125C TJ = 0 to 125C VIN - VOUT = 3V to 40V VIN - VOUT = 3V to 50V VOUT 5V VOUT 5V TA = 25C CADJ = 0 CADJ = 10mF TJ = 0 to 125C -1.262 -1.280 0.010 0.030 25 0.5 50 1 0.020
LM137A SERIES LM137A SERIES
Parameter
Test Conditions IOUT = 10mA IOUT = 10mA to IMAX VIN - VOUT = 3V to VMAX P PMAX TJ = 0 to 125C VIN - VOUT = 3V to VMAX TJ = 0 to 125C IOUT = 10mA to IMAX
IP337HV LM337HV Min. Typ. Max. -1.213 -1.200 -1.25 -1.250 0.010 0.020 15 0.3 20 0.3 0.003 60 66 77 65 0.5 2 3 2.5 1 1.5 0.15 0.1 2.2 0.4 0.4 0.6 0.3 0.003 2.3 4 3 1 0.8 100 5 5 6 10 6 3.5 -1.287 -1.300 0.040 0.070 50 1 70 1.5 0.04
Units V V
VREF
Reference Voltage
DVOUT Line Regulation 1 DIOUT DVOUT Load Regulation 1 DIOUT
%/V mV % mV % %/W dB dB
mA mA
DIADJ
(HV SERIES)
TJ = 0 to 125C VIN - VOUT 40V VIN - VOUT 10V VIN - VOUT 15V ICL Current Limit TJ = 0 to 125C VIN - VOUT = 40V VIN - VOUT = 50V
mA
A
(HV SERIES)
DVOUT Temperature TJ = 0 to 125C DTEMP Stability DVOUT Long Term Stability t = 1000 Hrs DTIME
en RqJC RMS Output Noise (% of VOUT) Junction to Case f = 10 Hz to 10 kHz TA = 25C T Package
% % % C/W
Thermal Resistance K Package
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to heating effects are covered under thermal regulation specifications. Load regulation is measured at a point 1/8" from the bottom of the package for the TO-3 and TO-66 packages, at the junction of the wide and narrow portion of the output lead for the SMD1 package, and 1/8" below the base of the package on the output pin of the TO-257 package. 2) Test Conditions unless otherwise stated: VIN - VOUT = 5V , IOUT = 0.5A , PMAX = 20W , IMAX = 1.5A VMAX = 40V for standard series , 50V for HV series.
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612. E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
Prelim. 7/00
IP137A SERIES IP137A SERIES IP337A SERIES IP337A SERIES
APPLICATIONS INFORMATION
High Stability Regulator
The output stability, load regulation, line regulation, thermal regulation, temperature drift, long term drift, and noise, can be improved by a factor of 6.6 over the standard regulator configuration. This assumes a zener has 20PPM/C maximum drift and about 10 times lower noise than the regulator.
LM137A SERIES LM137A SERIES
Multiple Tracking Regulators
In the application shown below, regulator #2 to "N" will track regulator #1 to within 24mV initially, and to 60mV over all load, line, and temperature conditions. If any regulator output is shorted to ground, all other outputs will drop to -2V. Load regulation of regulators 2 to "N" will be improved by VOUT / 1.25V compared to a standard regulator, so regulator #1 should be the one which has the lowest load current.
2 F R3 1 .5 k 1% R1 1k 1% 1F SO LID TANT ALUM C3 1 0F R2 C1 1F SO LID TAN TALU M
R 2* 7V
AD J VIN -VIN VOU T VIN
AD J
VOU T
R EG #1
1 N4 0 0 2
R1 1 20
* R2 =
IP337A
( VO U T ) - 908 9.08 x 10 -3
-VO U T
-VIN
-VO U T1
IP137A
IP3 17A
VIN +VIN ADJ
R1* * 1 00 1%
2 F
AD J
VOU T +VO U T VIN VOU T
R EG #2
1 N4 0 0 2
1F SO LID TANTA LU M
-VO U T2
IP137A
2. 2 F D1 1N40 02
1 0F
R2 5k 1%
2 F R3 5k
AD J
VIN VOU T
R EG #N
1 N4 0 0 2
1F SO LID TANTA LU M
1 0F
R4 5k 1% 2. 2 F D2 1N40 02
-VO UT N
I P 13 7 A
R5* * 1 00 1%
ADJ VIN -VIN VOU T -VO U T
C1 1 F
AD J (-)
VIN VOU T
SO LID TANA TALU M
IP3 37A
* Solid Tantalum ** R1 or R5 may be trimmed slightly to improve tracking.
RS
I (+)
IP337A
I = 65A + 1.25 V RS 0.8 R S 250
Dual Tracking Supply
Current Regulator
Order Information
Part Number LM137 LM137HV LM137A LM137AHV IP137 IP137HV IP137A IP137AHV LM337 LM337HV IP337 IP337HV IP337A IP337AHV K-Pack (TO-3) R-Pack (TO-66) IG-Pack G-Pack T-Pack (TO-257) (TO-220) SG-Pack Temp. SMD1 Range -55 to +150C " " " -55 to +150C " " " 0 to 125C 0 to 125C 0 to 125C " 0 to 125C "
Prelim. 7/00
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612. E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk


▲Up To Search▲   

 
Price & Availability of LM337HV

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X